${message}
Hager MCCB h630 3P 50kA 250A LSI HND250H
Product Code: HND250H
£${displayPrice} ${vatBit}
Description:
Moulded Case Circuit Breaker h630 3P 50kA 250A LSIRated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2 | 85 kA |
Correction factor of rating current for 6 devices placed side-by-side | 1 |
Number of mechanical operations | 4000 |
Electric endurance in number of cycles | 1000 |
Altitude | 2000 m |
Number of poles | 3 P |
CE marking on label | AI2_B5_CE_01.JPG |
Correction factor of rating current for 4 and 5 devices placed side-by-side | 1 |
Frequency | 50;60 Hz |
Range of the magnetic adjustment | 1400 / 1750 / 2240 / 2800 / 3150 / 3250 / 3250 A |
Tightening torque | 22Nm |
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2 | 50 kA |
Breaking capacity on 1 pole with 400 V NF 60947-2 | 9 kA |
Protection index IP | IP4X |
Rated current | 250 A |
Thermal protection nob setting xIN | 0.4 / 0.5 / 0.63 / 0.8 / 0.9 / 0.95 / 1 |
DIN rail mounting with optional adaptator | No |
Trip Unit | LSI |
Correction factor of rating current for 3 devices placed side-by-side | 1 |
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2 | 50 kA |
Connection | Front connection |
Correction factor of rating current for 2 devices placed side-by-side | 1 |
Category of use | A |
Power loss per pole at In | 8.2 W |
Compatible with DIN rail mounting | No |
Rated insulation voltage | 800 V |
Rated operational voltage Ue | 220 / 690 V |
European directive WEEE | concerned |
Integrated earth fault protection | No |
Complete device with protection unit | Yes |
With under voltage release | No |
Pol type for printing of stamps | 3 P |
Air humidity protection | for all climates |
Storage temperature | -35/70 °C |
Operating temperature | -25/70 °C |
Type of pole | 3P3D |
Connection cross-sect. flexible conductor | 35 ; 240mm² |
Rated impulse withstand voltage | 8000 V |
Type of order | Toggle |
Connection cross-sect. rigid cable | 35 ; 240mm² |
Type of connection | Terminal |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as normally closed contact | 0 |
Tripmode | LSI |
Time of response when opening | 10 ms |
Total power loss under IN | 24.6 W |
Standard text | IEC 60947-2 |
Number of auxiliary contacts as change-over contact | 0 |
Motor drive optional | Yes |
Search words | Compact circuit-breaker;Circuit-breaker;Main switch;Switch;Circuit-breaker;MCCB; |
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2 | 85 kA |
Number of modules | 8 |
EAN | 3250613349530 |
Unit | PCE |
Sales status | 3C |
Instruction manuals for HND250H | 2173 kb | Download | |
Commercial Distribution Catalogue | 13011 kb | Download |