Hager MCB 3P 15kA C-100A 4.5M HMC390T

Hager MCB 3P 15kA C-100A 4.5M HMC390T

Hager

HMC390T
£120.57 incl. VAT

- +

MCB 3P 15kA C-100A 4.5M
Concurrently switching N-neutral No
Product categories described in the W3E directive 2012/19/EU Category 5
Rated insulation voltage 500 V
Rated operational voltage Ue 415 V
Type of supply voltage AC
Type of pole 3 P
Type of connection terminal with tightening compensation system
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2 15 kA
Rated current 100 A
Frequency (range for ETIM) 50/60 Hz
Altitude 2000 m
Bottom removability for modular devices Yes
Correction factor of rating current for 2 devices placed side-by-side 1
Correction factor of rating current for 3 devices placed side-by-side 0.95
Correction factor of rating current for 4 and 5 devices placed side-by-side 0.9
Correction factor of rating current for 6 devices placed side-by-side 0.85
Tightening torque 3,5 to 5Nm
Curve C
Degree of pollution according to IEC 60664 / IEC 60947-2 3
Overvoltage category according to IEC 60947-1 3
Type of top rail clip for modular devices Plastic
Number of protected poles 3
Frequency 50;60 Hz
Height of installed product 90 mm
Breaking capacity on 1 pole with 400 V NF 60947-2 4.5 kA
Breaking capacity on 1 pole with 415 V NF 60947-2 4.5 kA
Rated short circuit breaking capacity Icn AC according IEC60898-1 15 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1 15 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1 15 kA
Rated service breaking capacity Ics AC according IEC 60947-2 50 %
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2 15 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2 15 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2 15 kA
Top connection alignement for modular devices Aligned terminal
Rated impulse withstand voltage 6000 V
Type of top connection for modular devices with screw
Rating current 55°C according to IEC 60947-2 89.4 A
Rating current 45°C 89.4 A
Rating current 45°C according to IEC 60947-2 96.6 A
Rating current 50°C 85.6 A
Rating current 50°C according to IEC 60947-2 93.1 A
Rating current 5°C 120 A
Rating current 55°C 81.6 A
Rating current 40°C 93.1 A
Rating current 60°C 77.5 A
Rating current 60°C according to IEC 60947-2 85.6 A
Rating current 65°C according to IEC 60947-2 81.6 A
Rating current 70°C according to IEC 60947-2 77.5 A
Protection index IP IP20
Bottom connection alignement for modular devices Aligned terminal
min/maxi threshold value of the AC thermal operation 1.13 / 1.45 In
Rating current 40°C according to IEC 60947-2 100 A
Rating current 35°C according to IEC 60947-2 104 A
CE marking on label AI2_B5_CE_01.JPG
Rating current 10°C 116 A
Rating current 10°C according to IEC 60947-2 124 A
Rating current 15°C 112 A
Rating current 150°C according to IEC 60947-2 120 A
Rating current 20°C 108 A
Rating current 35°C 96.6 A
Rating current 20°C according to IEC 60947-2 116 A
Rating current 25°C 104 A
Rating current 25°C according to IEC 60947-2 112 A
Rating current 30°C 100 A
Rating current 30°C according to IEC 60947-2 108 A
Temperature of calibration 30 °C
Magnetic regulating currrent at 40° C 5 / 10 In
Width of installed product 80 mm
Nominal tightening torque bottom terminal 3.6 Nm
Connection cross section of access and exit with screws, for flexible conductor 1 / 50 mm²
Connection cross-section at output with screw, for massive conductor 1 / 70 mm²
Connection cross-section for rigid conductor, upstream terminals with screws 1 / 70 mm²
Rating current 0°C 124 A
Connection cross-sect. flexible conductor 50mm²
Operating temperature -25/70 °C
Storage temperature -25/80 °C
Nominal tightening torque top terminal 3.6 Nm
Connection cross-section at output with screw, for flexible conductor 1 / 50 mm²
Air humidity protection for all climates
European directive WEEE concerned
Standard text EN 60898-1 ; IEC 60947-2 ; AS ; NZS 60898-1
Top removability for modular devices Yes
Type of Bottom Connection for modular devices with screw
Type of bottom rail clip for modular devices plastic
Connection cross-section of the access with screws, with flexible conductor 1 / 50 mm²
Connection cross-section of input and output with screws, for massive conductors 1 / 70 mm²
Connection cross-sect. rigid cable 70mm²
Electric endurance in number of cycles 4000
Number of poles 3 P
Number of modules 4.5
Quantity of half modules of 17,7mm 9
Number of mechanical operations 20000
Total power loss under IN 21.66 W
360° product mounting position Yes
Depth of installed product 70 mm
Power loss per pole at In 7.98 W
Unit PCE
Sales status 3C
EAN 3250613231286
Documentations
Commercial Distribution Catalogue 13011 kb pdf Download

We Also Recommend


Contact

Address: 362 Upper Richmond Road West, SW14 7JT, London

E-mail: shop@cewgroup.co.uk

Phone: 0800 133 7425



Payment icons
  • American Express
  • Apple Pay
  • Google Pay
  • Maestro
  • Mastercard
  • Shop Pay
  • Visa