Hager MCB 2P 10kA/15kA B-40A 2M NBN240A Box of 6 – CEW Group
${shop.name} SELECT BRANCH
Cart ${totalCartItems}
Total: £${totalCart}
Shipping: £0.00
FOUND IT CHEAPER? Let us know and we'll do our best to match it! GET IN TOUCH
sale! All Hager products 5% off

Prices are VAT inclusive

Hager MCB 2P 10kA/15kA B-40A 2M NBN240A Box of 6

Hager MCB 2P 10kA/15kA B-40A 2M NBN240A Box of 6

Hager

NBN240A
£288.31 incl. VAT

- +

MCB 2P 10kA/15kA B-40A 2M
Suitable for flush-mounting Yes
European directive WEEE concerned
Storage temperature -25/80 °C
Operating temperature -25/70 °C
Connection cross-section of the access with screws, with flexible conductor 1 / 25 mm²
Connection cross-section for rigid conductor, upstream terminals with screws 1 / 35 mm²
Connection cross-section at output with screw, for massive conductor 1 / 35 mm²
Top removability for modular devices Yes
Connection cross-section at output with screw, for flexible conductor 1 / 25 mm²
Power loss per pole at In 3.36 W
Total power loss under IN 6.7 W
Standard text EN 60898-1 ; IEC 60947-2
Type of top connection for modular devices with screw
Type of Bottom Connection for modular devices BIconnect
Type of bottom rail clip for modular devices plastic
Bottom connection alignement for modular devices Aligned terminal
Type of top rail clip for modular devices NA
Top connection alignement for modular devices Aligned terminal
Type of pole 2 P
Type of supply voltage AC
Rated operational voltage Ue 400 V
Minimum threshold voltage (Ue min) 12 V
Rated insulation voltage 500 V
Rated impulse withstand voltage 6000 V
Product categories described in the W3E directive 2012/19/EU Category 5
Concurrently switching N-neutral No
Maximum power loss per pole according to the product standard 7.5 W
Classification of the product (residential or commercial) Commercial product
Depth of installed product 70 mm
Rating current 0°C 51.51 A
Rated service breaking capacity Ics under 240V AC according IEC 60898-1 7.5 kA
Rated service breaking capacity Ics AC according IEC 60898-1 7.5 kA
Rated service breaking capacity Ics under 220V AC according IEC 60947-2 15 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2 15 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2 15 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2 30 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2 30 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2 30 kA
Rated current 40 A
Rating current 0°C according to IEC 60947-2 60.53 A
Rated service breaking capacity Ics under 220V AC according IEC 60898-1 7.5 kA
Rating current -10°C 55.35 A
Rating current 10°C 48.06 A
Rating current -10°C according to IEC 60947-2 64.1 A
Rating current 10°C according to IEC 60947-2 56.57 A
Rating current -15°C 56.7 A
360° product mounting position Yes
Rating current 150°C according to IEC 60947-2 54.59 A
Rating current -20°C 58.43 A
Rating current -20°C according to IEC 60947-2 68.43 A
Rating current 20°C according to IEC 60947-2 52.62 A
Rated service breaking capacity Ics under 230V AC according IEC 60898-1 7.5 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1 10 kA
Rating current 25°C 42.87 A
Correction factor of magnetic tripping with 60 Hz 1.1
Altitude 2000 m
Bottom removability for modular devices Yes
Can be accessorized Yes
Class of energy limitation I²t 3
Correction factor of magnetic tripping with 100 Hz 1.1
Correction factor of magnetic tripping with 200 Hz 1.2
Correction factor of magnetic tripping with 400 Hz 1.5
Correction factor of rating current for 2 devices placed side-by-side 1
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1 10 kA
Correction factor of rating current for 3 devices placed side-by-side 0.95
Correction factor of rating current for 4 and 5 devices placed side-by-side 0.9
Correction factor of rating current for 6 devices placed side-by-side 0.85
Tightening torque 2,8Nm
Curve B
Degree of pollution according to IEC 60664 / IEC 60947-2 2
Frequency (range for ETIM) 50/60 Hz
Overvoltage category according to IEC 60947-1 3
Number of protected poles 2
Height of installed product 83 mm
Rating current -25°C 60.15 A
Rating current -15°C according to IEC 60947-2 66.46 A
Rating current -25°C according to IEC 60947-2 70.41 A
Upstream cage clamp delivery status opened
Rating current 65°C according to IEC 60947-2 34.82 A
Rating current 70°C 27.31 A
Rating current 70°C according to IEC 60947-2 32.85 A
Protection index IP IP20
Magnetic regulating currrent at 40° C 3 / 5 In
Rating current 25°C according to IEC 60947-2 50.64 A
min/maxi threshold value of the AC thermal operation 1.13 / 1.45 In
min/maxi threshold value of the DC thermal operation 1.13 / 1.45 In
Downstream cage clamp delivery status opened
Rating current 60°C according to IEC 60947-2 36.8 A
Temperature of calibration 50 °C
CE marking on label AI2_B5_CE_01.JPG
Width of installed product 35 mm
Quantity of half modules of 17,7mm 4
Number of modules 2
Number of poles 2 P
Electric endurance in number of cycles 4000
Number of mechanical operations 20000
Neutral position without neutral
Rating current 65°C 29.04 A
min/maxi threshold value of the DC magnetic operation 4 / 7 In
Rating current 40°C 37.68 A
Rating current 50°C according to IEC 60947-2 40 A
Rating current 35°C 39.41 A
Rating current 40°C according to IEC 60947-2 44.71 A
Rating current 45°C 35.96 A
Rating current 45°C according to IEC 60947-2 42.73 A
Rating current -5°C 53.24 A
Rating current 30°C according to IEC 60947-2 49.8 A
Rating current 50°C 34.99 A
Rating current 30°C 40 A
Rating current 5°C 49.78 A
Rating current 60°C 30.77 A
Rating current 55°C 32.5 A
Rating current 55°C according to IEC 60947-2 38.78 A
Rating current -5°C according to IEC 60947-2 62.5 A
Rating current 5°C according to IEC 60947-2 58.55 A
Rating current 35°C according to IEC 60947-2 46.69 A
Fixing mode Din-Rail
Compatible with DIN rail mounting Yes
With fault indicator No
With transparent product label holder Yes
Unit PCE
EAN 3250614618239
Sales status 3C
Documentations
Product environmental profile for NBN240A 433 kb pdf Download
Product data sheets for NBN240A 205 kb pdf Download
Commercial Distribution Catalogue 13011 kb pdf Download

We Also Recommend


Contact

Address: 362 Upper Richmond Road West, SW14 7JT, London

E-mail: shop@cewgroup.co.uk

Phone: 0800 133 7425



Payment icons
  • American Express
  • Apple Pay
  • Google Pay
  • Maestro
  • Mastercard
  • Shop Pay
  • Visa